WebBackground: One million Total Hip Replacements (THA) are thought to be performed annually. To measure prosthesis awareness throughout daily activities, the FJS-12 patient-reported outcome scale was developed. This article’s goal is to undertake a psychometric validation of the Italian FJS-12 among a sample of related THA patients. … WebJan 19, 2024 · The Fitmore Hip Stem is a short and curved uncemented stem that allows preservation of the greater trochanter and of the gluteal muscles. Indication/Target Population: Patients suffering from severe hip pain and disability requiring total hip arthroplasty. Study Design: A multi-centre, non-comparative, prospective post-marketing …

Hip Replacement Surgery Johns Hopkins Medicine

WebHip replacement, also called hip arthroplasty, is a surgical procedure to address hip pain. The surgery replaces parts of the hip joint with artificial implants. The hip joint consists of a ball (at the top of the femur, also … WebThe Fitmore® hip stem (Zimmer, Warsaw, Ind) is a bone-conserving stem designed for use in MIS techniques. The technique described here is a single-incision ante-rior approach with the Fitmore stem using a special orthopedic table. T otal hip arthroplasty (THA) is one of the most successful orthopedic procedures. The first ante- flower with money bouquet https://gloobspot.com

Use of the Fitmore® hip stem bone-preserving system for …

WebEcho Bi-Metric Microplasty Stem. Part of Zimmer Biomet’s Echo Hip System, this stem is designed for minimally invasive surgical procedures. The stem of the Echo Bi-Metric … WebArthroplasty is performed over 100,000 times each year and has a 90% success rate. Many seniors who need hip replacement surgery are understandably concerned about the … WebThe OPTION is comprised of two components: BIOLOX ®delta ceramic femoral head Adapter sleeve The titanium adapters have an internal 12/14 taper that mates with the femoral stem while the OPTION heads have a … greenbushes postal code

Zimmer Hit with a Serious Hip Replacement Part Recall

Category:Cortical hypertrophy with a short, curved uncemented hip stem …

Tags:Fitmore hip replacement

Fitmore hip replacement

Cortical hypertrophy with a short, curved uncemented hip stem …

WebMay 27, 2024 · The Fitmore hip stems settled within the first year to a stable fixation and then remained almost unchanged. However, cortical thinning is common in Gruen Zone 7 and 8 meaning that there is stress-shielding. Keywords: Clinical relevance; Cortical hypertrophy; Fitmore; Long term; Short stem. MeSH terms Aged WebNancy Crotti. FDA recently announced a Class I designation for a Zimmer hip replacement parts recall.. Certain Zimmer M/L taper with Kinectiv technology femoral stems and necks have "unexpected amounts of …

Fitmore hip replacement

Did you know?

WebCurrently, an increasing number of younger patients undergo total hip arthroplasty surgery. This has led to a minimal invasive approach and the use of short, bone preserving, …

WebJan 1, 2016 · Implatation of cementless endoprosthesis with Fitmore Hip Stem in the treatment of secondary hip osteoarthritis , is a good choice in the treatment of young patients with good bone quality ... WebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the …

WebJun 26, 2013 · Description. The Tri-Lock Bone Preservation Stem is an uncemented tapered wedge design primary hip replacement stem. The original Tri-Lock was introduced in 1981 as the first proximally coated … WebFitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option [14].

WebMar 21, 2011 · Use of the Fitmore® hip stem bone-preserving system for the minimally invasive anterior-supine approach in hip replacement. Am J Orthop (Belle Mead NJ). 2010 Oct;39 (10 Suppl):13-6 Have you used this device? Your opinion matters to others - rate this device or add a comment Similar Devices 1-5 of 22 Sort By: Tri-Lock Bone Preservation …

WebThe Johns Hopkins Hip and Knee Replacement program features a team of orthopaedic specialists highly skilled in joint replacement procedures. Our team will guide you through every step, from presurgical education … flower with petals falling offWebJan 7, 2024 · The aim in templating a Fitmore hip stem is to restore the anatomical offset by confirming that the medial curve of the stem follows closely to the inner line of the cortex in the calcar region when the stem is in axis with the femoral canal. ... Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am … flower with one petalWeb5 Fitmore Hip System - Ordering Information Fitmore General Instrument Set Product Description Size Quantity Product Number Fitmore Curved Hand Rasp – 1 00-7942-020 … greenbushes primaryWebJun 30, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) . A cementless titanium press-fit cup with or without screws (Allofit®/-S, ZimmerBiomet, Warsaw, IN, USA) was used in all ... greenbushes postcodeWebJan 7, 2024 · On the other hand, studying the metaphyseal-anchored Fitmore hip system (Fitmore®, Zimmer Inc., Warsaw, IN, USA), Gustke described subsidence of more than 2 mm on plain radiographs in 34% of 100 examined THA after a mean follow-up of 1.3 years. However, none of these implants had to be revised during this short follow-up . In our … greenbushes postcode waWebThe aim of this paper was to present the early postoperative results in patients with implanted Fitmore® hip stem and point out some of the advantages. Methods: A series of 10 patients with implanted Fitmore® hip stem, was included in this study. The average age of the patients was 54.5 (48–65) years. There were 5 women and 5 men. greenbushes pool waWebFitmore Hip Stem This represents functional compatibility and does not necessarily indicate regulatory approval status for marketing of product pairs. Document #: 87-6204-951-00 Revision: 1 Head and Stem Combinations: Zimmer Biomet 12/14 CoCr Femoral Heads and Freedom Heads greenbushes post office